Welcome Guest | |
Live Chat
Call Back
Submit Your Sourcing Requirement
Advanced Search Filtersdown arrow
Print

Astek Globe Co., Ltd.

Company Summary:

  • Since 2013
  • 11-15 Employees
  • Turnover 100,000.00 USD per year
  • 100% turn over from existing products
  • 80 year(s) of Export Experience
  • Corporation

Additional Contacts:

www.astekglobe.com
Export Department
Roger Lin
Phone: +886 - /+886 - 0937579000
Fax: +886 -

Company Address:

Chung Hsiao E. Rd.,
Taipei City
Taiwan, 201
Web Page Link: https://www.toboc.com/astekglobecoltd

GET A QUOTE

Details of Product or Sell Offer
product

AGM040 40W Medical Desktop Adapter

"AGM040 40W Medical Desktop Adapter" is listed under  Switching Power SuppliesCategory

Features*Universal AC Input Range *DOE VI/CoC 5*Protections: Overcurrent/ Overvoltage/Short Circuit*Means of Patient Protection Design*Possess risk analysis report* UL, cUL60601, EN/IEC60601 with 3rd Edition and CE, FCC approved.*Warranty two Years*Application: Medical power, Medical charger(CV mode), Power Supply for Health careInput Voltage: 90~264VACFrequency: 50~60HzInput current: 1A max. Leakage Current: 0.1mA max. @240VAC /50Hz Inrush current: 50A @115VAC 90A @230VAC at 25& 176C cold start OutputPart No Rated O/P(current max.) Ripple & Noise(mV p-p) AGM040-S05-z 5-6V/5-4.17A/25W 150AGM040-S75-z 6-8V/5-3.75A/30W 150AGM040-S09-z 8-11V/4.5-3.27A/36W 150AGM040-S12-z 11-13V/3.63-3.07A/40W 150AGM040-S15-z 13-16V/3.07-2.5A/40W 200AGM040-S18-z 16-21V/2.5-1.9A/40W 200AGM040-S24-z 21-27V/1.9-1.48A/40W 200AGM040-S27-z 27-33V/1.48-1.21A/40W 300AGM040-S48-z 33-58V/1.21-0.68A/40W 300z: C6/C14/C8 inletMechanical Drawing General Specification Load Regulation: +/-5 Percent Max.Line Regulation: +/-1 Percent Max. Insulation resistance: 50Mohm min. from Input to output Over Current Hiccup mode auto-recovery, rate output current >110 Percent Over Voltage Protection: Protected by Zerner diode, Rated output voltage 110~140 PercentShort circuit Protection: auto recovery Hiccup mode Setup/Hold up/ Rise time: Typ.: 1000mS/10mS/50mS at full loadEfficiency : DOE VIDerating : Derated from 100 Percent at +40& 176C linearly to 50 Percent at +70& 176CTemperature Coefficient: All output +/-0.04 Percent / & 176C max.Withstand Voltage: 5656VDC from input to outputOperating Temperature: 0~40degree CStorage Temperature: -40~85degree CStorage Humidity: 5~95 Percent RHTransient Response: Max. Excursion of 4 Percent better on all models. Recovering to 1 Percent of final value within 500uS. after a 25 Percent step load changeEMC: EN600601-1-2: 2007, FCC Part 15 & Part 18 class BSafety: UL60601-1: 2005, CSA: C22.2 60601-1: 2008, EN60601-1:2006



Product Detail

medical adapter
30     USD Per Pieces
1000     Pieces
8   week(s)
30000   Pieces Monthly
DOE VI adapter, desktop adapter, medical adapter
#DOEVIadapter, #desktopadapter, #medicaladapter

View All Products posted by Astek Globe Co., Ltd.


You may be interested in.
Guangzhou Top Power Electronics Technology Ltd.
>