Sell Lead Product Details
Three hours smart fast charger
"Three hours smart fast charger" is listed under sector : Chargers
1 Product Features
1.1 Application Range
Suitable for 1~4 pieces of AA /1~4pieces of AAA Ni-Cd or Ni-MH batteries
1.2 Microprocessor Controlled
1.2.1 –Delta v/0 Delta v cut off
The charger stops charging once the microprocessor detects the batteries are fully charged.
1.2.2 Timer Protection
For safety use, charging termination is controlled with timer.
1.2.3 Defective and Non-rechargeable battery detection
Safety Protection for using the charger if you attempt to charge defective or non-rechargeable batteries. If you
charge non-rechargeable and rechargeable together, detection may not work properly.
Charging rechargeable alkaline batteries may result in battery leakage.
1.3 Other protections
1.3.1 Reverse Polarity Protection
Protects the charger and batteries against incorrectly installing batteries.
1.3.2 Over Current Protection
Maintains constant charging current during the charging cycle.
1.4 Low Battery Leakage Current
If the battery charger is not connected to AC power and the batteries are left in the charger, the charger will
discharge the batteries in a certain amount of current.
1.5 Trickle Charge After Full Charge
After batteries are fully charged, there will still be a small pulse charge current applying to batteries.
1.6 Charging Indicators
Red indicates CHARGING
Green indicates batteries are FULL charged and on trickle charging
Red/Green Flashing indicates WARNING of
Defective batteries
Short circuit
2 Electrical Performance and Technical Parameter
2.1 Input :
100~240VAC 50/60Hz 10W ;12~14V DC 1.0A (Max. )
2.2 Charging Currents
AA/AAA×2 700~800mA for 1~2 batteries
AA/AAA×4 300~400mA for 3~4 batteries
2.3 Charging Voltages
1.4V for individual charge
2.4 Battery Leakage Current
Maximum 0.5mA
2.5 High-Voltage Shock Test
Method: Connecting high voltages 3000VAC for 1 minute between input and output terminals.
Requirement: Current leakage between input/output must be less than 10mA, and the unit should still work as
normal.
3 Mechanical Tests and Requirements
3.1 Drop test
Drop from 3 feet height onto an oak board of 10 mm thick. The test shall be carried out 3 times
respectively in 3 different surfaces of the case.
Requirement: The charger should still meet High-Voltage Shock Test.
3.2 Bending test (Electrical cord)
Loading: The plug and S/R should withstand weight of 200 gram.
Cycles: Swing 120o left to right for1000 cycles.
Speed: 20 cycles/min.
Expected result: The cord should still be conductible.
3.3 Surface
Damage and rusting are not permitted.
4 Environmental Conditions
4.1 Operating Temperature
0C to 40C, best at 25±2C
4.2 Storage Temperature
-20C to 60C, best at 25±5C
4.3 Normal operation humidity range
Below 85%R.H., non-condensing
5 Safety Standards
CE Approval
6 Product Inspections
6.1Inspections to 100% of products
Charging voltages
Charging current
LED indicators (except for FULL)
Foreign mass & sound by shock
Polarity of charging channel
Surface
Charging AA or AAA at least once at 25±3C.
6.2 Inspections to part of products
Over current protection
Drop test
View all sell products posted by
Shenzhen Spowerking Technology Co.,LTD
View All Products posted by
Shenzhen Spowerking Technology Co.,LTD
You may be interested in.