Welcome Guest | |
Live Chat
Call Back
Submit Your Sourcing Requirement
Advanced Search Filtersdown arrow

Dexing Magnet Tech. Co., Ltd

Company Summary:

  • Since 1985
  • 51-75 Employees
  • Turnover 5,000,000.00 USD per year
  • 95% turn over from existing products
  • 10 year(s) of Export Experience
  • Limited Company

Additional Contacts:

Export Department
Jackie Tsui
Phone: +86 - 0592 - 5558386/ -
Fax: +86 - 0592 - 5237901

Company Address:

Unit 404,4/F,No.993, Anling Road,Huli District, Xiamen, China 361012
Xiamen, Fujian
China, 361012
Web Page Link: http://www.toboc.com/dexingmagnettechcoltd767937


Details of Product or Sell Offer

DX-2012H DC Hysteresis Graph Test System for Hard Magnet

"DX-2012H DC Hysteresis Graph Test System for Hard Magnet" is listed under  Testing EquipmentCategory

DX-2012H DC Hysteresis Graph Test System Automatic measurement of the demagnetization curve of permanent magnetic material such as ferrite, AlNiCo, NdFeB, SmCo, etc. Accurate measurement of the magnetic characteristic parameters of Remanence Br, coercive force HcB, intrinsic coercive force HcJ and maximum magnetic energy product (BH)max.Windows measurement software applied simply. The product conforms to China National Standards GB/T 3217-92, GB 11209-89 and international standard IEC 404-5. Adopt ATS structure, users can customize different configuration as required: According to the intrinsic and size of measured sample to decide the electromagnetic size and corresponding testing power supply Select different measuring coil and probe according to the option of measuring meth`od. Decide to whether choosing fixture in accordance with sample shape. Decide to whether selecting heating installation or not according to the test requirement. General Features of DC Hysteresis Graph (DX-2012H)Automatic measurement on saturation hysteresis loop and magnetic characteristic parameters of generally permanent-magnet material such as Ferrite, Rubber & Plastic Magnet and AlNiCo, etc.: Js, Br, HcB, HcJ, (BH)max and & 181rec.Automatic measurement on demagnetization curve and magnetic characteristic parameters of rare earth permanent-magnet materials such as NdFeB and SmCo, etc. at the second quadrant: Br, HcB, HcJ, Hk(H90) and (BH)max.Test sample shapes: circular ring, round cake, square, tile and other irregular shapes.Adopt B coil + fluxmeter to measure magnetic induction, zero shift of integrator can be self-corrected through software.Adopt J coil + fluxmeter to measure magnetic polarization, remnant coil area of J coil can be automatically compensated through software.Magnetic field intensity can be measured with Hall magnetometer, nonlinear error of hall probe can be corrected through software, within 0 ~ 2.4T range, nonlinear error can be controlled within& 1770.2 Percent.Adopt H coil + fluxmeter to measure magnetic field intensity, Hall magnetometer only used to indicate zero point of magnetic field so as to thoroughly eliminate nonlinear error of hall probe.Optimal range of field voltage, fluxmeter and magnetometer can be automatically set up.Magnetization, testing and demagnetization of general permanent magnetic sample completed at one time, time set up 20 seconds ~ 60 seconds.Rare earth permanent magnetic samples need saturation magnetizing before testing, testing time 60 seconds ~ 120 seconds.The sample after tested is in demagnetization or magnetizing status, freely selected by users.Select heating head and temperature controller to detect magnetic characteristics of Ferrite, AlNiCo and rare earth material under high temperature (maximal 220& 176C).Select shoe jig for direct measurement on magnetic shoe. Technical Data of DC Hysteresis Graph (DX-2012H)System Specifications Test AlNiCo standard sample, measuring error on entire magnetic hysteresis cycle estimated: B: 1 Percent, H: 1 Percent Parameters measured Br( Percent)HcB( Percent)HcJ ( Percent)(BH)max( Percent)Uncertainty (k=2)1112Repeatability (constant temperature)& 177 0.3& 177 0.3& 177 0.3& 1771Instrument SpecificationsTPS-2000H Test Power Supply DCT150 Electromagnet Output Voltage: 0 ~& 177100VOutput Current:& 17720A (maximum value)Stability: superior to 0.05 Percent Stability: superior to 0.05 Percent Head Diameter: 150mm shrink to 80mmHead Spacing: 0 ~ 50mm (continual adjustable)Maximal Magnetic Field: 2.4T (head spacing 10mm, coil current 30A)LZ-210B FluxmeterDCT200 Electromagnet Range: 2.5, 5, 10, 20mWb Full Range Precision: 0.5 Percent Zero Shift: 2& 181Wb /30 seconds (2.5mWb)Head Diameter: 200mm shrink to 120mmHead Spacing: 0 ~ 50mm (continual adjustable)Maximal Magnetic Field: 2.4T (head spacing 10mm, coil current 40A)LZ-210H MagnetometerDCT250 Electromagnet Range: 0.5, 1, 1.5, 3T Full Range Precision: 0.5 Percent Non-L

Product Detail

42     AUD Per Sets
1     Sets
30   day(s)
100   Sets Monthly
Hysteresis, Hysteresis Graph, VSM
#Hysteresis, #HysteresisGraph, #VSM

View All Products posted by Dexing Magnet Tech. Co., Ltd

You may be interested in.
Jaya Equipment Store